Permit: T03CM04820

Parcel: 123053510


Addresses:

2207 E WAVERLY ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/24/2003 FRAMING Approved IVRS - Inspection 0000*
12/17/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) MIXING OF ABS AND PVC NOT ALLOWED 2) REVISE PLAN FOR USE OF AIR ADMITANCE VALVE AT LAVS 3) NAIL PROTECT PEX WITHIN 1 1/4" OF STUD SURFACE 4) 4 X 12 BEAM MUST BE FULL BEARING AT SOUTH EAST CORNER 5) RIDGE BEAM BEARING OVER OPEN POCKET AND THEN ON 8' LINTEL-PROVIDE APPROVED ENGINEERING OR AS BUILT DETAIL
12/11/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) REVISE PLAN TO REFLECT AS BUILT
12/05/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) VENT FAN AT SHOWER MUST EXTEND COMPLETELY TO EXTERIOR 2) DID NOT FIND PLAN/PERMIT ON SITE 3) SUPPORT HVAC VENTS WITH BLOCKING