Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/20/2004 FRAMING Approved IVRS - Inspection 0000*
01/15/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) LEAK AT BATHROOM W/C VENT 2) BATHROOM W/C VENT UNDERSIZE DUE TO WET VENT OF LAV 3) COPPER CONDENSATE CANNOT BE INCONTACT WITH GALVANIZED DRYER VENT OR BLACK GAS PIPE 4) POST TENSION SLAB CUT FOR PLUMBING REPAIR-PROVIDE ENGINEERS APPROVED REPAIR 5) NO PLUMBING PLAN ON STIE (PAGE 6) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 7) FLOOR CUT SEE ITEM 4
01/12/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) FINISH MESHING REAR GABLE, SEAL DOOR BELL WIRE 2) NAIL OFF FHA STRAPS AT GAS MAIN RISER 3) BANG PLATE WIRES AT TOP PLATE ON BACK OF WATER HEATER, SOUTH OF GARAGE MAN DOOR, BOTH SIDES OF ENTRY WINDOW AND EAST BED EAST TOP PLATE 4) SHIM HEADERS WHERE NEEDED 5) TIGHTEN HOLDOWNS 6) STAPLE WIRE AT HALL ENTRY SWITCH 7) EXTEND FURNACE PLATFORM TO HATCH 8) RE-RUN CUT TPR DRAIN LINE