Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04793

Parcel: 13105122A


Addresses:

5382 E 32ND ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/19/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
11/24/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROWS OF ROOF NAILING MISSING AT NORTH PLANE OF HIP AND AT ENTRY ROOF. ALSO, NAIL ROOF TO BIRD BOARDS 2) PROVIDE VIEW HOLES AT TOP AND BOTTOM OF ENTRY COLUMN 3) INSTALL COIL STRAP AT GABLE TRUSS ENDS AND HEADERS WHERE NEEDED 4) PLAN CALLS FOR 24" SOFFIT OVERHANGS AND BIRD BOARD VENTS 5) NAIL OFF WALL OSB AT FRONT DOOR JAMBS 6) TRUSS CALC'S CALL FOR MECHANICAL CONNECTION OF TRUSS CG1 AT POINT #6
11/21/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*