Permit: T03CM04789

Parcel: 120010350


Addresses:

4376 S VALLEY RD


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM04789

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2004 FRAMING Approved IVRS - Inspection 0000*
11/25/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*
11/21/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) OK TO DRYWALL-CHECK FOR SUPPORTING CRIPPLE STUD IN MIDDLE BEDROOM RETURN AIR SUPOPORTING PLATE SPLICE AT FINAL INSPECTION
11/20/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) WALL TOP PLATE BREAKS (SPLICES) MUST OCCUR OVER BEARING MEMBER
11/19/2003 FRAMING Denied IVRS - Inspection 0950*/ 1) SEAL ALL PENETRATIONS 2) LATH NOT COMPLETE 3) GROUND ALL METAL ELETRIC BOXES PROPERLY 4) SHEAR PANELS IN TRUSSES NOT PROPERLY NAILED 14/DT1 5) BOND GAS LINE 6) RECESSED LIGHT REQUIRES 1/2" COMBUSTIBLE 7) HEADER MUST BEAR ON TRIMMERS 8) 1/2" CLEARANCE REQUIRED BETWEEN SCISSOR TRUSSES AND NON-BEARING WALL 9) W/C REQUIRES 15" CLEARANCE TO TUB 10) STOPPED INSPECTION, TOO MANY ITEMS