Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/09/2004 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/25/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 11/21/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO DRYWALL-CHECK FOR SUPPORTING CRIPPLE STUD IN MIDDLE BEDROOM RETURN AIR SUPOPORTING PLATE SPLICE AT FINAL INSPECTION |
| 11/20/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) WALL TOP PLATE BREAKS (SPLICES) MUST OCCUR OVER BEARING MEMBER |
| 11/19/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) SEAL ALL PENETRATIONS 2) LATH NOT COMPLETE 3) GROUND ALL METAL ELETRIC BOXES PROPERLY 4) SHEAR PANELS IN TRUSSES NOT PROPERLY NAILED 14/DT1 5) BOND GAS LINE 6) RECESSED LIGHT REQUIRES 1/2" COMBUSTIBLE 7) HEADER MUST BEAR ON TRIMMERS 8) 1/2" CLEARANCE REQUIRED BETWEEN SCISSOR TRUSSES AND NON-BEARING WALL 9) W/C REQUIRES 15" CLEARANCE TO TUB 10) STOPPED INSPECTION, TOO MANY ITEMS |