Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/02/2004 | FRAMING | Approved | ||
12/02/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) 24" ON CENTER REAR SHEAR 2) NAIL OFF SHEAR 3" ON CENTER 3) ADD H.D. AT GARAGE DOOR | |
12/01/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) #5 SHEAR WALLS 2) NAIL OFF ALL OSB SHEAR 3) 3" ON CENTER BROKEN CONCRETE ANCHOR BOLTS NORTH. 3" ON CENTER NAILING 8D'S. AB'S AT 24" ON CENTER 4) MISSING H.D. AT HOUSE TO GARAGE DOOR |