Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T03CM04768

Parcel: 141176030

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
11/17/2003 ROOF NAILING Approved IVRS - Inspection 0000*
11/14/2003 ROOF NAILING Partial Approval IVRS - Inspection 0000*
11/10/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*/ 1) NAIL OFF AW MARKED ROOF DECK. 2) ENDS OF LARGE X BRACES ARE SPLIT AT NAILS. SOME NAILS NOT DRIVEN HOME. 3) NEED TRUSS DRAWINGS. 4) SHEAR PANELS, FRONT ENTRY, MADE TOO SHORT. 5) NEED MORE NAILS IN GARAGE LEDGER - L6BDS - NOT 10S. 6) BOTTOM CHORD TRUSS 2' LONG BROKEN AT FRONT TOWER. 7) ALL BLKS INSTALLED A HOLES IN SHEAR DON'T DO ANY THING UNLESS THEY ARE NAILED TO SHEATHING