Permit: T03CM04768

Parcel: 141176030

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T03CM04768

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/17/2003 ROOF NAILING Approved IVRS - Inspection 0000*
11/14/2003 ROOF NAILING Partial Approval IVRS - Inspection 0000*
11/10/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*/ 1) NAIL OFF AW MARKED ROOF DECK. 2) ENDS OF LARGE X BRACES ARE SPLIT AT NAILS. SOME NAILS NOT DRIVEN HOME. 3) NEED TRUSS DRAWINGS. 4) SHEAR PANELS, FRONT ENTRY, MADE TOO SHORT. 5) NEED MORE NAILS IN GARAGE LEDGER - L6BDS - NOT 10S. 6) BOTTOM CHORD TRUSS 2' LONG BROKEN AT FRONT TOWER. 7) ALL BLKS INSTALLED A HOLES IN SHEAR DON'T DO ANY THING UNLESS THEY ARE NAILED TO SHEATHING