Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/17/2003 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/14/2003 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000* |
| 11/10/2003 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NAIL OFF AW MARKED ROOF DECK. 2) ENDS OF LARGE X BRACES ARE SPLIT AT NAILS. SOME NAILS NOT DRIVEN HOME. 3) NEED TRUSS DRAWINGS. 4) SHEAR PANELS, FRONT ENTRY, MADE TOO SHORT. 5) NEED MORE NAILS IN GARAGE LEDGER - L6BDS - NOT 10S. 6) BOTTOM CHORD TRUSS 2' LONG BROKEN AT FRONT TOWER. 7) ALL BLKS INSTALLED A HOLES IN SHEAR DON'T DO ANY THING UNLESS THEY ARE NAILED TO SHEATHING |