Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03CM04757
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/06/2004 | PLUMBING - FINAL | Approved | 1) PETITION OF APPEAL ALLOWS WATER HEATER IN CURRENT LOCATION 2) CORRECTIONS MADE OK 3) PLUMBING FINAL OK 4) OK FOR C OF O PENDING ANY OTHER INSPECTION | |
01/15/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) RELOCATED WATER HEATER STILL ABOVE 8 FEET. 2) INDIRECT WASTE PIPING MORE THAN FIVE FEET MEASURED ALONG THE CENTERLINE SHALL BE DIRECTLY TRAPPED. SUPPORT PIPING. |