Permit: T03CM04752

Parcel: 113031780


Addresses:

926 E KING ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/17/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*SENT TO TEP ON 11/18AM
10/27/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0215*/ 1) 15 PSI TEST DID NOT HOLD FOR 15 MINUTES 2) BEFORE RECALLING FOR INSPECTION BE SURE WATER HEATER IS COMPLETELY INSTALLED. REMOVE THE COFFEE CAN FROM CONNECTION TO FURNACE VENT. ELECTRIC CORD ON FURNACE REQUIRES A ROMEX CONNECTOR. BE SURE WATER HEATER HAS A TEMPERATURE AND PRESSURE RELIEF DRAIN AND MUST BE 3/4" THE WHOLE WAY. PUT 3 SCREWS IN EACH JOINT OF VENT CONNECTORS. MUST HAVE ACCESS TO INSIDE HOUSE TO CHECK STORE AND CLOTHES DRYER. RETEST SYSTEM AND BE SURE THEREW ARE NO LEAKS. MUST HOLD MINIMUM 10 POUNDS FOR 15 MINUTES. THE GAS TO WATER BOND IS INCORRECT. THE COLD WATER PIPING IS THE PIPING COMMON TO ALL APPLIANCES, SINKS, ETC. AND IS THE PIPE WHICH MUST BE BONDED TO THE GAS LINE. PLEASE CORRECT
10/13/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) PLEASE INDICATE WHERE GAS BOND IS LOCATED 2) LOOPING OF GROUND WIRE THROUGH ? CLAMP INSTITUTE 2 CONDUCTORS IN ? CLAMP. NOT LISTED FOR 2 ( DOUBLE BACK)