Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM04702
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/16/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/15/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) STC CLIPS NOT INSTALLED PER MANUFACTURERS INSTALL INSTR. 2) FIRE BLOCKS MISSING 3) NAIL PROTECT ELECTRIC WITHIN 1 1/4 FROM EDGE 4) SECURE WATER LINES AT HALL BATH 5) NAIL PROTECT DRYER VENT BOTH SIDES | |
01/13/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO TEST ON DWV'S OR WATER LINES 2) NO TEST ON GAS LINE 3) INSPECTION (MARK) SUPER, STOPPED |