Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04684

Parcel: 125122640


Addresses:

3444 E 4TH ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
09/24/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/24/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/30/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) PROVIDE PIMA CO WW APPROVAL FOR ADDED SHOWER 2) PROVIDE APPROVED PLAN FOR MASTER BATH
08/26/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) JACCUZI TUB NOT LOCATED PER PLAN. REVISE AND PROVIDE PROOF OF DRAIN/VENT INSPECTION 2) PLAN CALLS FOR KITCHEN TO VENT TO ROOF. BUILD TO PLAN OR RIVISE 3) NAIL PROTECT PLUMBING ON KITCHEN EAST/WEST WALL WITHIN 1 1/4" OF SURFACE 4) BOND GAS LINE 5) BOND COPPER WATER LINE 6) CANNOT APPROVE RECONNECT UNTIL FINAL. STOPPED INSPECTION PENDING PLAN REVISION