Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM04660
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ 1) PETITION OF APPEAL FOR WATER HEATER LOCATION ON SITE 2) REVISED PLAN SHOWING RELIEF AND PAN TERMINUS OK 3) OK TO COVER ALL AREAS | |
| 11/14/2003 | PLUMBING - INTERMEDIATE | Partial Approval | SUBJECT TO APPROVED REVISED PLAN ON LOCATION OF RELEIF LINES & PAN DRAINS. WILL REQUIRE APPEAL. TEST ON WASTE VENTS & WATER OK | |
| 11/13/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) SEE 511.2 94 UPC LOCATION OF WATER HEATER. 2) OFFSET CLOSET FLANGES NOT ALLOWED. 3) NO WATER TEST ON PVC. 4) PLEASE POST CORRECT ADDRESS. 5) ROOF DRAINS OK. WATER TEST OK. PLUMBER TO SUPPORT TO INSTALLATION STANDARD I.E. - CHANGE OF DIRECTION OR ELEVATION AND EVERY 4 FEET. 6) OK TO SHEET ROCK ONE SIDE AND CEILING. |