Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/26/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/25/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NAIL OFF PLY TO GARAGE LEDGER, MARKED IN RED 2) NAIL OFF ENTIRE FRONT PORCH, INCLUDING LEDGER UNDER 2 X 4 ABOVE FOR ROOF TILE 3) CHECK WITH PREVIOUS SUPER TRUSS DRAWINGS SHOW 3 PT BEARING, I DON'T THINK THAT THEY ARE, SHOULD HAVE DRAWINGS SHOWING BEARING AS 2 PT OUT TO OUT |