Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/26/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 04/16/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) SUPPORT VENT 90 DEGREE 2) FHA STRAP TOP PLATES WHERE NEEDED 3) SHIM HEADERS WHERE NEEDED 4) REMOVE STAPLES/NAILS WHERE NEEDED-NEAR WIRING OR PEX 5) GROUT TUB DRAIN HOLE 6) GROUND ALL METAL BOXES WITH GREEN SCREW 7) OUTLETS MUST BE LOCATED WITHIN 6' OF EVERY DOOR WAY AND THEN EVERY 12' MAXIMUM HERE ON 8) FINISH MESH AND CAULK ALL PROTRUSIONS | |
| 04/12/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) COMPLETE LATH BEFORE INTERMEDIATES |