Permit: T03CM04639

Parcel: 11446027E

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03CM04639

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/11/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*/ 1) OK FINAL
06/08/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ OK TEMP C OF O.
06/07/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ 1) KITCHEN OUTLETS TO BE GRID PROTECTED. 2) BREAKER AMPACITY FOR CENTERLINE 8 NM CABLE TO BE AS PER 336-26.
06/01/2004 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*/ CANCELLED BY CONTRACTOR.
05/26/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ 1) OK UNITS 113, 114, 115, 116, 213, 214, 215, 216, 312, 314, 315 AND 316 TO CLEAR
05/17/2004 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) LIGHTING ON OUTDOOR WALL TO MEET CITY LIGHTING ORDINANCE REQUIREMENTS SECTION 5. LIGHT IS A 150 W HPS. 2) BOXES MORE THAN ΒΌ" FROM BOX TO SURFACE IN NON-COMBUSTABLE TO HAVE APPROVED EXTENDER RINGS - METAL NOT APPROVED 370-20. 3) BREAKERS HAVE BEEN PAINTED OVER MAKING IT UNABLE TO READ OVER CURRENT RATINGS - EXCESSIVE PAINT ON TERMINALS, ALSO LABELED, 110-12, 110-22. 4) PLEASE INSTALL HOOD. 5) CONDUIT ON OUTSIDE OF BLDG TO BE REMOVED BACK TO 1ST JUNCTION BOX AND SEALED. / LEFT PAPERWORK FOR TEMP POWER FOR TEST.