Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/28/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/25/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) HOLDOWN AT SW GARAGE JAM LOOSE 2) OK TO INSULATE AND DRYWALL ALL BUT H.D. |
| 11/24/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ITEMS 1, 2, 6 AND 7 FROM 11/21/03 NOT COMPLIED WITH |
| 11/21/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) HOLDOWN BOLTS LOOSE 2) ANCHOR BOLTS MISSING THROUGHOUT GARAGE 3) HALL W/C IMPROPERLY VENTED 4) FIRE STOP STAIR 6) SHEAR WALL MISSING OSB 7) NO GAS BOND 8) OK TO INSULATE |