Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM04593
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2004 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 01/22/2004 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) GROUNDED OUTLETS INSTALLED IN UNGROUNDED CIRCUITS MUST EITHER BE UNGROUNDED OUTLETS OR FIRST OUTLET MUST BE GFCI PROTECTED AND ALL OUTLETS LABELED UNGROUNDED GFCI OUTLETS 2) FRONT NORTH BEDROOM HAS INADEQUATE EGRESS. MUST HAVE MINIMUM OF 20" WIDE OPENING PRESENTLY 15" ( ALSO NORTH REAR BEDROOM ) 3) LAUNDRY WASTE LINE MUST HAVE A " P " TRAP 4) DUPLEX HAS BEEN REMODELED UNDER ONE PERMIT 5) REAR UNIT BATHROOM ELECTRIC OUTLET MUST BE GFCI PROTECTED 6) REAR UNIT ALL KITCHEN OUTLETS MUS BE GFCI PROTECTED 7) ALL CEILING IN FRONT UNIT EXCEPT BEDROOMS HAVE 6'-10" HEIGHT | |
| 01/21/2004 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) PROVIDE SHUT OFF VALVE WATER HEATER ? 2) GFCI OUTLET AT BATHROOM 3) ADDRESS MUST BE POSTED |