Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04587

Parcel: 13011209A


Addresses:

2320 S HEMLOCK SV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/08/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/03/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) EXTERIOR WALL TO NORTH MOVED 3" 2) 5 FOOT EXTENSION BEARING ON SINGLE TOP PLATE, NEEDS DOUBLE TOP PLATE 3) NO 6 X 8 BEAMS EXISTING, DBL 2 X 10'S 4) CLIPS MISSING NAILS 5) NOT BUILT PER PLAN, ANY DEVIATIONS MUST BE TAKEN BACK TO DEVELOPMENT SERVICES FOR RE-APPROVAL