Permit: T03CM04577

Parcel: 116062760

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
03/01/2004 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000* NOTES: BARRIER @ WATER HEATER AND DRIP LEG TO BE INSPECTED @ FINAL.
02/27/2004 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) INSTALL DRIP LEGS AT FURNACE/WATER HEATER 2) EXTEND TPR TO EXTERIOR 3) INSTALL BARRIER AT WATER HEATER 4) COMBUSTION/RETURN AIR WITHIN 12" OF CEILING AND FLOOR 5) REMOVE TAPE SEALING B-VENTS 6) SEPARATE COPPER FROM INCOMPATIBLE METAL 7) NOTES: FIRE STOP WATER HEATER STAND AND SHAFT AT TOP PLATE