Permit: T03CM04577

Parcel: 116062760

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
01/30/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) DOES NOT INCLUDE ROUGH-INS
01/28/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) EXCEPT FRAMING AT SOUTH WEST CORNER (ROUNDED) 2) TRUSSES REVIEWED-OK
01/21/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) H2.5 KING AT GARAGE 2) PROVIDE TRUSS CALC'S 3) SOUTH/WEST (ROUNDED) CORNER TOP PLATE IS NOT TO CODE AND THE TRUSSES ARE NOT SUPPORTED. ALSO BOTTOM PLATE 4) INSTALL BLOCKING AT TRUSS BOTTOMS, FRONT AND REAR PER PLAN 5) STRAP HEADERS TO KINGS 6) H2.5 GIRDER-BOTH SIDES 7) STRAP ALL CORNERS NOT CABIN TIED 8) TOO MANY ITEMS TO LIST, STOPPED