Inspection Status: Partial Approval
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/30/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) DOES NOT INCLUDE ROUGH-INS |
| 01/28/2004 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) EXCEPT FRAMING AT SOUTH WEST CORNER (ROUNDED) 2) TRUSSES REVIEWED-OK |
| 01/21/2004 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) H2.5 KING AT GARAGE 2) PROVIDE TRUSS CALC'S 3) SOUTH/WEST (ROUNDED) CORNER TOP PLATE IS NOT TO CODE AND THE TRUSSES ARE NOT SUPPORTED. ALSO BOTTOM PLATE 4) INSTALL BLOCKING AT TRUSS BOTTOMS, FRONT AND REAR PER PLAN 5) STRAP HEADERS TO KINGS 6) H2.5 GIRDER-BOTH SIDES 7) STRAP ALL CORNERS NOT CABIN TIED 8) TOO MANY ITEMS TO LIST, STOPPED |