Permit: T03CM04574

Parcel: 141014610

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM04574

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/09/2004 FRAMING Approved IVRS - Inspection 0000*
01/05/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) CHECK FOR FIRE BLOCKING 2) ROMEX NOT ALLOWED TO BE STAPLED ON IT'S SIDE 3) NO TEST ON DWV'S 3) LAUNDRY ROOM VENT NOT GLUED 4) NO TEST ON GAS LINES 5) WATER LINE MUST BE 12" AWAY FROM CAN LIGHTS 6) 2" TRAP ARM NOT ALLOWED FOR LAV 7) STOPPED INSPECTION TO MANY ITEMS HAVE TRADES AND SUPERVISOR WALK HOUSE BEFORE RECALL