Permit: T03CM04571

Parcel: 10309074A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM04571

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*/ 1) ADDITIONAL FLOOR SINK SUBJECT TO APPROVED PLAN. 2) CORRECTIONS MADE OK. 3) OK TO BACKFILL.
11/04/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) YOU MUST CORRECT THE ADDRESS ON THE PERMIT BEFORE THE NEXT INSPECTION 2) PLEASE REMOVE DEBRIS FROM TRENCH WHERE IT IS COVERING CONNECTIONS 3) REQUIRED 2 PIPE DIAMETERS BETWEEN WEIR OF TRAP AND POINT OF VENT AT FLOOR SINK INSTALLED AT SERVICE SINK AREA NOT ON PLAN. REVISE PLAN OR INSTALL PER APPROVED PLAN
11/03/2003 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*/ DOORS LOCKED - NO ACCESS.