Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 03/31/2005 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* 1) OK TO COVER ALL AREAS |
| 03/30/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* 1) TRAP ARMS WHICH EXCEED 1/4" PITCH PER FOOT RISK HAVING THE POINT OF VENT BELOW THE TRAP WEIR, WHICH PROMOTES SIPHONAGE-CHECK ALL TRAP ARMS AND CORRECT THE PITCH AS REQUIRED |
| 03/29/2005 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :* 1) THIRD FLOOR-STILL SUPPORTING FITTINGS-NOT PIPE. PIPE SUPPORTS TO BE ADJACENT TO FITTINGS, NOT ON THEM. 2) WATER PIPING MAY NOT PASS OVER ELECTRIC SERVICE PANEL. 3) 2ND FLOOR-POINT OF VENT MAY NOT BE BELOW THE??OF THE TRAP |
| 03/28/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* 1) SUPPORT PIPE, NOT FITTINGS. 2) SECURE ALL CLOSET FLANGES WITH APPROVED SCREWS. TRAP ARMS TO BE INSTALLED WITH 1/4" PITCH PER FOOT. |
| 03/25/2005 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |