Permit: T03CM04540

Parcel: 141176000

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM04540

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2004 FRAMING Approved IVRS - Inspection 0000*
02/04/2004 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) MOVE PEX AT SHOW LIGHT CAN 2) H.D. NO BOLT BEHIND TUB 3) SEE LIST LAST INSPECTION
01/28/2004 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) MOVE CONDENSATE LINES AWAY FROM LIGHT CANS (KITCHEN) 2) ALIGN WALL KITCHEN AT REFER WATER 3) NO PRESSURE ON WATER LINES 4) MOVE DRYER METAL BOX OVER DON'T COMPRESS FLUE, SECURE NAIL PROTECTION AT TOP PLATE 5) NO NUTS ON HD'S 6) INSULATE LARGE METAL CANS MECH 7) SW5 SHEARWALLS, A.B. AT 32" ON CENTER 8) MOVE PEX AWAY FROM LIGHT CAN EAST BATH 9) BACKING AT SHOWER PAN 10) INSUALTE TUB WEST WALL 11) BLOCK MECHANICAL FRONT ENTRY