Permit: T03CM04531

Parcel: 122153120

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/09/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/28/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* PROVIDE LISTING ON GREASE INTERCEPTOR
08/31/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
08/30/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/PA
1)WATER RISER #1 = 3 § KITCHEN
2)WATER RISER #2 § CLASSROOM 118
3)ROUGH FOR ROOM #104 & 103 TEST OK
$) WILL RECEIVE TEST ON VENTS AT TOP OUT. ALSO HCS BETWEEN BLDG DRAIN-SITE SEWER 3-LOCATION OK
NOTE: DON'T FORGET FINE? CAULK IN FLOOR PENATRATION
08/27/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/PARTIAL ON K-2 - K-6=1ST FLOOR WILL NEED TO INSULATE & INSTALL CLOSET COLLERS
TEST ON WASTE VENTS & WATER-OK AT THIS TIME.
JERRY MILLER ON JOB SITE-TAP OK
ACS. FOR MULTIPURPOSE BUILDING-
PARTIAL TEST OK PLEASE PROVIDE APPROVAL FROM WASTE WATER FOR TAP IN WRITING FOR OUL RECORDS
PARTIAL ON 4" SITE SEWER TO TODDER BUILD WILL NEED TO TIE IN TO EXISTING HCS & BLD DRAIN
08/26/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/NR-CALL JIM 349-5029
PLEASE PROVIDE APPROVAL FROM PIMA COUNTY WWM ON NEW LOCATION OF HCS MACHINE CUT ON ABOVE ADDRESS. I HAVE NO INFORMATION ON MINIMUM SPACING OF FIVE FT. BETWEEN TAP'S ON 1 CONNECTION PER LENGTH OF MAINLINE, AS PER MANUAL OF ENGINEERING STANDARDS AND PROCEDURES PIMA COUNTY WASTE WATER MANAGEMENT.
PLEASE PROVIDE THIS APPROVAL IN WRITING BEFORE APPROVAL IS GIVEN BY THIS OFFICE.
NOT READY FOR INSP TEST WYE? UPSIDE DOWN PLEASE CORRECT & CALL AGAIN RE TEST
08/24/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/PA-PLEASE PROVIDE HISTORY ON INTERCEPTOR
OK--TEST OK IN KITCHEN AREA. SOIL & GREASE SEE PLAN
08/23/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*/NOT READY FOR INSPECTION
08/20/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
07/15/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ 1) PVC UNDERGROUND AT INFANT/BATHROOMS-OK 2) WATER TEST ONE RISER TO TEN FEET-OK 3) OK TO COVER 4) AS INFERED BY CORRESPONDANCE, ALTERNATE METHODS TO ACCEPTED PRACTICES ARE APPROVED WHEN ACCOMPANIED WITH PETITION OF APPEAL. VARIENCE SHALL BE ON SITE AT TIME OF INSPECTION
06/29/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ 1) VENT AND WASTE CONNECTION FOR SEWER EJECTION SYSTEM IS OK. 2) OK TO BACKFILL TRENCH.
05/28/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ 1) PVC DWV UNDERGROUND INSTALLED PER PLAN. SEWAGE EJECTOR NOT INSTALLED. 2) OK TO BACKFILL. 3) SEE 807.2 94 UPC. - CONDENSATE WASTE MAY NOT BE DIRECTLY CONNECTED TO A SINK TAILPIECE.
05/19/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/ WOMANS WASHROOM B-25 UNDERGROUND ROUGH TEST OK. OK TO BACKFILL.