Permit: T03CM04497

Parcel: 140374700


Addresses:

6188 E BRAMBLE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/30/2003 FRAMING Approved IVRS - Inspection 0000*
12/29/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE #3 AND #5 FROM LAST INSPECTION
12/22/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NO TEST ON DWV'S 2) SEE LAST INSPECTION
12/19/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) ANCHOR BOLT NUTS NOT TIGHT AT GARAGE SHEARWALL 2) PLUMBERS TAPE NOT ALLOWED FOR ABS SUPPORT 3) ANCHOR BOLTS MISSING WITHIN 12" OF CUT PALTE BEHIND 3" ABS 4) SECURE GAS LINE IN ATTIC 5) ROMEX NOT ALLOWED TO BE STAPLED ON IT'S SIDE. PER TABLE 3702.1 2000 IRC 6) WATER LINES OK