Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04490

Parcel: 116035150


Addresses:

2431 W PAINE TR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/28/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/27/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP CORNERS AND PEAKS. 2) A35 TRUSSES PER DETAIL #10. 3) NAIL SHEAR #4 AT OVERSHOT (LOOSE SHEATHING.) TRUSSES REVIEWED - OK.