Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM04466
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/17/2003 | FRAMING | Denied | IVRS - Inspection 0999* 1) MECH NO TCOMPLETE.2) FHA STRAP CUT DONGLE TOP PLATES. 3) ANCHOR BOLTS REQUIRED WITHIN 6" OF SHEAR PANEL ENDS.4) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD/WALL SURFACE.5) UFFR GROUND NOT CONNECTED. 6) FLOORS & FITTINGS WET UNABLE TO INSTALL D W V. STOPPED INSP HOUSE NOT READY. |