Permit: T03CM04455

Parcel: 140373980


Addresses:

6209 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/18/2003 FRAMING Approved IVRS - Inspection 0000*
12/15/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) REPAIR FLEX DUCT AT DINING AREA 2) DUCT HANGING IN DINING AREA 3) SECURE ELECTRICAL WIRES AT GARAGE 4) UFER NOT INSTALLED TO MAIN PANEL 5) NAIL PROTECT ALL ELECTRICAL WIRES WITHIN 1 1/4" FROM EDGE OF STUD 6) ROMEX NEEDS TO BE SECURED WITHIN 8" FROM BOX UPSTAIRS HALL 7) SECURE GAS LINE AT LAUNDRY ROOM 8) INSULATE BEHIND TUBS 9) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT FURNACE FLUE
12/09/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) MECHANICAL INCOMPLETE 2) SECURE PLUMBING ABS THRU-OUT 3) ELECTRIC INCOMPLETE 4) FILL TUBS FOR TEST 5) MECHANICAL BLOCKS MISSING 6) AB'S MISSING, STOPPED INSPECTION, TOO MANY ITEMS