Permit: T03CM04448

Parcel: 116172470


Addresses:

1003 W ERIE ST #01


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM04448

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
06/29/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ CORRECTIONS MADE OK. OK TO COVER ALL AREAS.
06/15/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) WTR TEST ON DWV INCOMPLETE - EACH SECTION OF PIPE AND EVERY FITTING SHALL BE WTR TESTED (AIR). 2) A C.O. TEE MAY BE USED AS A VERTICAL WALL SURFACE C.O. C.O. EXTENSIONS SHALL BE THRU A WYE BRANCH OR EQUIVELENT. 3) INSTALL CLOSET FLANGES.