Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04446

Parcel: 108163600

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/26/2004 FRAMING Approved IVRS - Inspection 0000*
01/22/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) NUMBERS 2, 8 AND 9 FROM LAST INSPECTION 2) BANG PLATE WIRES AT FRIDGE 3) NEED MID-SPAN X BRACING 4) FIREBLOCK EAST END OF ENTERTAINMENT COUNTER 5) SHIM EAST LIVING WINDOW HEADERS AND TRIMMERS
01/21/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) BANG PLATE ELECTRIC AND PEX BEHIND WATER HEATER 2) NO WATER PRESSURE OR WATER FOR DWV 3) TC CLIPS NOT NAILED OR MIS-NAILED IN GARAGE/LAUNDRY 4) BLOCK DUCT BOOT IN 1/2 BATH 5) FIREBLOCK EAST DINING WALL CHASE 6) FRONT TRUSSES IN MASTER CLOSET H2.5 ON NORTH SIDE ? 7) NEED RED HEAD UNDER MASTER PICTURE WINDOW 8) REMOVE ROOFING FROM SOUTH FURN. FLUE 9) SUPPLY TRUSS CALCS FOR NEXT INSPECTION