Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T03CM04429
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/25/2004 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*/ NO ROOF DRAINS - REVISED PLAN ON SITE. | |
02/18/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*/ WTR TEST ON 4" GREASE WASTE STUBBED INTO BLDG AND 4" SANITARY WASTE STUBBED INTO BLDG. OK FOR STUBS ONLY. THIS REQUIRES CITY APPROVED PLAN WITH INSTALLATION OF 2-WAY CLEAN-OUT ON GREASE WASTE INLET AND 3" VENT FROM GREASE INTERCEPTOR AS WELL AS SIZE OF SANITARY SEWER INTO BLD AND ORIENTATION OF GREASE INTERCEPTOR. | |
02/13/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*/ TEST ONLY - PROVIDE APPROVED REVISED PLANS. |