Permit: T03CM04429


Addresses:

68 N HARRISON RD


Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T03CM04429

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2004 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*/ NO ROOF DRAINS - REVISED PLAN ON SITE.
02/18/2004 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*/ WTR TEST ON 4" GREASE WASTE STUBBED INTO BLDG AND 4" SANITARY WASTE STUBBED INTO BLDG. OK FOR STUBS ONLY. THIS REQUIRES CITY APPROVED PLAN WITH INSTALLATION OF 2-WAY CLEAN-OUT ON GREASE WASTE INLET AND 3" VENT FROM GREASE INTERCEPTOR AS WELL AS SIZE OF SANITARY SEWER INTO BLD AND ORIENTATION OF GREASE INTERCEPTOR.
02/13/2004 PLUMBING - SEWER HCS CONNECT Partial Approval IVRS - Inspection 0000*/ TEST ONLY - PROVIDE APPROVED REVISED PLANS.