Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM04416
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/26/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE ROOF JACKS ON ALL PENETRATIONS ON ROOF 2) COMPLETE INSTALLATION OF ROOF MOUNTED UNITS 3) CONDENSATION LINES SHALL BE TRAPPED WITH POSITIVE DRAIN 4) KITCHEN SINK STILL S-TRAPPED |
|
08/24/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEGATIVE FLOW ON PTR LINE 2) CAP BLDG C.O. AT GRADE 3) SECURE WATER HEATER DIVERTER AND VENT WITH SCREWS 4) PTR DISCHARGE 24" MAXIMUM FROM EARTH 5) SHIM RAFTERS AT FRONT ENTRY BEAM. CHECK PREVIOUS WRITE-UP DATED 8/23/04 6) NEED APPROVED PLANS ON SITE |
|
08/23/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) S-TRAP INSTALLED AT KITCHEN SINK, NO VENT OR CLEANOUT 2) FRONT PORCH LEDGER AND RAFTER CONNECTIONS, NOT SECURE, RAFTER SHOULD HAVE A HNAGER 3) POSTS EMBEDDED IN CONCRETE 4) USE ALL MANUFACTURERS TYPE BREAKERS IN SERVICE 5) H20 HTR COM/RELIEF AIR RELIEF DUCT TO BE WITHIN 12" OF CEILING 6) LOUVERS ARE RE-STRICTING AIR FLOW 7) DISHWASHER DRAIN HOSE NOT INSTALLED 8) FRONT ENTRY ROOM CEILING FIXTURE NOT INSTALLED 9) JACCUZZI TUB PANEL REMOVED-OK 10) ISLAND AT KITCHEN COUNTER REQUIRES AN OUTLET 11) MOVE OUT RANGE FOR INSP. 12) LADDER NOT LONG ENOUGH TO ACCESS ROOF 13) INTERMEDIATES NOT SIGNED OFF 14) NEED COMPLETE SET OF PLANS 15) A OUTLET AT KITCHEN COUNTER NED TO REFRIGERATOR | |
08/13/2004 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
08/09/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |