Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM04403
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2004 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/05/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MINIMUM 22 X 30 ATTIC ACCESS 2) SAFETY GLAZE 2020 WINDOW < 2' FROM DOOR 3) BAD GUAGE ON GAS TEST 4) PARTIAL ON MECH PENDING RE-DRAW OF MECH PLAN 5) OK TO INSULATE AND ROCK EXCEPT BATH WALL TO BE HEADERED OFF | |
03/17/2004 | FRAMING | Denied | IVRS - Inspection 0999* SAFETY GLAZE W/IN 24" OF DOOR. FIRESTOP FURNACE STAND. SUPPORT GAS @ HINGE JOINTS. BOND COPPER. 2X4 STUDS @ EXTERIOR MAX 16"O.C. GROUT TUB. SLEEVE 220V @ A/C THROUGH STUCCO. NOTCHES IN MIDDLE SPAN OF JOISTS NOT APPROVED. HEADER OFF STUD @ BATH. INSTALL ATTIC ACCESS W/ 30" CLEAR HEADROOM. EXTERIOR SHEATHING HAS NOT BEEN APPROVED. | |
03/12/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ LOCKED - NO ONE ON SITE. | |
01/15/2004 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) REMOVE ROOFING MATERIAL 1" FROM WATER HEATER FLUE 2) INSTALL COPPER JUMPER BOND WIRE FROM PLENUM TO DUCT 3) RETURN AIR CHAMBER, UNDER FURNACE, MUST BE COMPLETELY CLOSED IN AND SEALED 4) FRAME IN DUCT BOOTS | |
12/24/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* COMPLETE ALL TRADES | |
12/23/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE SUPPORT AT A/C STAND AND SURROUNDING WALLS. 2) INSTALL ABS WITHIN 12" OF JOINTS IN SOLE PLATE. 3) INSTALL ATTIC ACCESS. 4) BLOCK AND NAIL SHEAR AT JOINTS. 5) PROVIDE SUPPORT AT BATH WALL FOR CUT 2X6 AT LAV. |