Permit: T03CM04403

Parcel: 123152870


Addresses:

1117 E LEE ST #02


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM04403

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2004 FRAMING Approved IVRS - Inspection 0000*
04/05/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) MINIMUM 22 X 30 ATTIC ACCESS 2) SAFETY GLAZE 2020 WINDOW < 2' FROM DOOR 3) BAD GUAGE ON GAS TEST 4) PARTIAL ON MECH PENDING RE-DRAW OF MECH PLAN 5) OK TO INSULATE AND ROCK EXCEPT BATH WALL TO BE HEADERED OFF
03/17/2004 FRAMING Denied IVRS - Inspection 0999* SAFETY GLAZE W/IN 24" OF DOOR. FIRESTOP FURNACE STAND. SUPPORT GAS @ HINGE JOINTS. BOND COPPER. 2X4 STUDS @ EXTERIOR MAX 16"O.C. GROUT TUB. SLEEVE 220V @ A/C THROUGH STUCCO. NOTCHES IN MIDDLE SPAN OF JOISTS NOT APPROVED. HEADER OFF STUD @ BATH. INSTALL ATTIC ACCESS W/ 30" CLEAR HEADROOM. EXTERIOR SHEATHING HAS NOT BEEN APPROVED.
03/12/2004 FRAMING Denied IVRS - Inspection 0999*/ LOCKED - NO ONE ON SITE.
01/15/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) REMOVE ROOFING MATERIAL 1" FROM WATER HEATER FLUE 2) INSTALL COPPER JUMPER BOND WIRE FROM PLENUM TO DUCT 3) RETURN AIR CHAMBER, UNDER FURNACE, MUST BE COMPLETELY CLOSED IN AND SEALED 4) FRAME IN DUCT BOOTS
12/24/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000* COMPLETE ALL TRADES
12/23/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE SUPPORT AT A/C STAND AND SURROUNDING WALLS. 2) INSTALL ABS WITHIN 12" OF JOINTS IN SOLE PLATE. 3) INSTALL ATTIC ACCESS. 4) BLOCK AND NAIL SHEAR AT JOINTS. 5) PROVIDE SUPPORT AT BATH WALL FOR CUT 2X6 AT LAV.