Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM04392
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/29/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) OK TOO NET | |
10/28/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) LOW GAS TEST 2) PIPE OUT OF WALL LIVING ROOM 3" ABS VERT. DRAIN 3) SHIM ALL STRONG BACK NOTCHES, DON'T NOTCH COLS. OR POSTS NOTHING IN THE CODE ADDRESSES NOTCHING COLS/POSTS 4) TOO MANY STRONG BACKS NOTCHED STUDS 5) NEED A REP FROM US HOMES OR ENGINEERING REF TRUSS AT VAULTED CEILING LEDGER, PROBLEM WITH HANGER NAILS SPI LUMBER IN TRUSSES 6) INSTALL ALL WINDOWS 7) FINISH LATH 8) FINISH SHEAR A.B.'S 9) 3/4" PVC CONDENSATE TO EXT. FROM 2ND FLOOR 10) BANG PLATE CEILING 3" ABS AT 90 DEGREE ELBOW AT SOFFIT FAMILY ROOM SIDE | |
10/27/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) LOW GAS PRESSURE TEST |