Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM04376
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
10/21/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | 1) WILL CHECK MAS ANCHORS AT TOP OUT INSPECTION 2) NAIL ALLL HORIZONTAL JOINTS IN SHEAR WALLS REAR | |
10/20/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NAIL OFF ALL BLUE MARKS ON ROOF PLUS AREA AT GARAGE (SHEAR) AT LEDGER. 2) ALL MAS ANCHORS 3 NAILS EACH SIZE, REMOVE OSB THAT KEEPS MAS ANCHOR AWAY FROM PLATE. 3) NAIL HORIZ JOINTS IN EXT. SHEAR AT BLKS. | |
10/17/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) AS PER GEORGE, SUPERINTENDENT |