Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2004 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :*APPROVED. | |
| 12/15/2004 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL ELECTRIC OUTLET BOXES IN GARAGE MUST BE AT LEAST 18" ABOVE FLOOR 2) MAKE UP (CONNECT) ALL GROUND WIRES IN ELECTRIC BOXES AND SECURE WITH A MECHANICAL FASTENER 3) GROUND ALL METAL ELECTRIC BOXES 4) PROVIDE A GROUND PIG TAIL FOR EACH SWITCH AND OUTLET 5) ELECTRIC UNDER GROUND TO GARAGE OK TO COVER 6) GROUND RODS OK TO COVER |
|
| 06/04/2004 | ELECTRIC - INTERMEDIATE | Partial Approval | CHANGED TO PARTIAL BY BSTEVENS 11/04/04 TO ALLOW FOR CONSTRUCTION OF GARAGE WHICH IS INCLUDED ON PLAN |