Permit: T03CM04367

Parcel: 125043180


Addresses:

2204 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
12/22/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*APPROVED.
12/15/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL ELECTRIC OUTLET BOXES IN GARAGE MUST BE AT LEAST 18" ABOVE FLOOR
2) MAKE UP (CONNECT) ALL GROUND WIRES IN ELECTRIC BOXES AND SECURE WITH A MECHANICAL FASTENER
3) GROUND ALL METAL ELECTRIC BOXES
4) PROVIDE A GROUND PIG TAIL FOR EACH SWITCH AND OUTLET
5) ELECTRIC UNDER GROUND TO GARAGE OK TO COVER
6) GROUND RODS OK TO COVER
06/04/2004 ELECTRIC - INTERMEDIATE Partial Approval CHANGED TO PARTIAL BY BSTEVENS 11/04/04 TO ALLOW FOR CONSTRUCTION OF GARAGE WHICH IS INCLUDED ON PLAN