Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 12/02/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK. 2) OK TO COVER ALL AREAS. |
| 11/26/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CONNECT SEWER AND INSTALL CHANGE OF DIRECTION CLEAN-OUT AND BRING TO GRADE. 2) YARDWATER PIPING NOT INSTALLED PER PLAN - [SEE SCHEMATIC]. REMINDER; PVC REQUIRES MIN. 12" OF COVER PLUS PIPING UNDER SIDEWALK COVERED WITHOUT INSPECTION. 3) GAS PIPING NOT SUPPORTED TO AT LEAST TABLE 3-1 94 UPC, BESIDES PLBRS TAPE NOT APPROVED STRAP. 4) NO TEST ON ABS. UNCOVER ALL ALTERED PIPING I.E. CLOSET BENDS. |
| 11/24/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |