Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM04349

Parcel: 116126750


Addresses:

1643 W DELAWARE ST

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
10/07/2003 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection 0000*/ 1) SCREWS USED FOR H1'S 2) DOUBLE TOP PLATE NOT INSTALLED 3) ANCHORS NOT INSTALLED 4) BEAM TO SMALL AT ROOF (4 X 4) 5) SUPPORT AT ADJOINING STRUCTURE NOT INSTALLED 6) BLOCKING AT JOISTS NOT INSTALLED 7) TOO MANY TO LIST. NOT A COMPLETE INSPECTION
09/18/2003 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection 0999*/ 1) EXPOSE FOOTING TO A DEPTH OF 12" TO VERIFY