Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2005 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :* APPROVED CLOSET FLANGS OK TUBS UPSTAIRS WATER TEST OK. ADDITIONAL HANGERS OVERHEAD OK. OK FOR GAS CARD WHEN WATER HEATERS VENTS ARE INSTALLED AND TERMINATED 2' ABOVE TOP OF VERTICAL WALL WHEN WITHIN 8' OF VERTICAL WALL. |
| 11/12/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 11/10/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 10/26/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 03/22/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) WATER SERVICE AT S.E. END OF BLDG ARE OK TO BACKFILL |
| 03/19/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) AIR PRESSURE AND METER PRESSURE TEST IS OK FOR (5) UNDERGROUND WATER SUPPLYS TO BLDG 2) NOTE: THIS INSPECTION IS FROM METER LOCATION TO 3' FROM BLDG ONLY-OK TO BACKFILL TRENCH 3) LETTER FROM ARCHITECT IS OK FOR USE OF PVC PIPING IN LIEU OF TYPE K COPPER |