Permit: T03CM04333

Parcel: 136404390

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
12/30/2003 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*
12/23/2003 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) 36" WORKING SPACE REQUIRED IN ATTIC. 2) CLIP AND PROVIDE HANGER FOR DBL TRUSS AT WEST BEDROOM REQUIRED AND DBL STUDS TO BE UNDER DBL TRUSSES. 3) SECURE ROMEX AT EXT. FIXTURE AT GARAGE. 4) FIXTURE BOX REQUIRED AT KIT CEILING. 5) SECURE BOTTOM PLATES, CHECK THRU OUT. 6) NAIL SHEER TRANSFER BLKS PER PLAN AT KITCHEN. 7) LIVING ROOM OUTLET NOT TO BE WIRED TO KIT. GFCS. 8) CHECK FO NAIL PROTECTION THROUGHOUT.