Permit: T03CM04314

Parcel: 138242580

Inspection Status: Not ready for Inspection

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
02/17/2004 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
02/17/2004 BUILDING - FINAL Approved IVRS - Inspection 0000*
02/12/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) ABS PLASTIC VENTS ON ROOF MUST BE UV PROTECTED WITH LATEX PAINT 2) WATER HEATER CIRCUIT HAS IMPROPER COLOR CODED WIRES WHITE CANNOT BE HOT 3) ALL KITCHEN COUNTER OUTLETS MUST BE GFCI PROTECTED 4) BEDROOM OUTLET HAS OPEN NEUTRAL 5) NO SMOKE DETECTORS IN BEDROOMS