Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03CM04301
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/22/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ 1) BATHROOM FACILITIES EXISTING. 2) PLUMBING FINAL OK. 3) OK FOR C OF O. PENDING ANY OTHER INSPECTION. | |
10/21/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/1) DRAINS AT ICE MAKER NOT APPROVED - INDIRECT WASTE PIPING BETWEEN 5&15 FEET NEED TO BE DIRECTLY TRAPPED. 2)MATERIAL TO BE APPROVED TYPE. 3) CHANGES DIRECTION TO BE MADE WITH FITTINGS. | |
10/20/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION 2) ALL FIXTURES TO BE CAULKED | |
10/17/2003 | PLUMBING - FINAL | Not ready for Inspection |