Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/22/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) BATHROOM FACILITIES EXISTING. 2) PLUMBING FINAL OK. 3) OK FOR C OF O. PENDING ANY OTHER INSPECTION. |
| 10/21/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) DRAINS AT ICE MAKER NOT APPROVED - INDIRECT WASTE PIPING BETWEEN 5&15 FEET NEED TO BE DIRECTLY TRAPPED. 2)MATERIAL TO BE APPROVED TYPE. 3) CHANGES DIRECTION TO BE MADE WITH FITTINGS. |
| 10/20/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION 2) ALL FIXTURES TO BE CAULKED |
| 10/17/2003 |
PLUMBING - FINAL |
|
Not ready for Inspection |
|