Permit: T03CM04294

Parcel: 129021350

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
05/05/2004 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :
See detailed listing on site.| 999*
04/28/2004 ELECTRIC - UNDERGROUND Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MAINTAIN MINIMUM 12" DIRT COVER OVER UNDERGROUND PIPING OUTSIDE 2) SECURE WIRES AWAY FROM FLUE PIPES 3) SECURE ELECTRIC WIRES WITHIN 12" OF BOXES 4) INSTALL BANG PLATES ALL ELECTRIC HOLES LESS THAN 1 1/4" FROM STUD FACE 5) SUB PANEL LOCATION NOT PER PLAN 6) SUBMIT AS BUILT DRAWINGS FOR APPROVAL 7) WHAT IS ROMEX STUBBED OUT OF WALL (SOUTH SIDE) ? AT 48" HEIGHT 2 LOCATIONS 1 AT 12" OFF FLOOR 8) STOPPED INSPECTION COMPLETE ALL AND RECALL