Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T03CM04253
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2004 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
| 03/08/2004 | PLUMBING - YARD WTR LINE/TEST | Partial Approval | 5' OUTSIDE AND 2½" H2O FEED TO 7160 E BROADWAY [SPORTMART] FROM 5' OUTSIDE SUBMETER ISLAND, 2½" H20 FEED TO 7150 E BROADWAY [MICHAELS] 5' OUTSIDE BLD TO 5' FROM SUBMETER ISLAND, 2" H20 FEED TO 7140 E BROADWAY [BIG D] FROM 5' OUTSIDE BLD TO 5' FROM SUBMETER ISLAND ALL 60 PSI TEST PARTIAL APPROVAL PENDING CITY APPROVED DRAWING SHOWING INSTALLATION. PROVIDE CITY APPROVED DRAWING SHOWING SIZING OF ALL PIPING FROM EXISTING METER THRU BACKFLOW DEVISE OR DEVISES TO ALL BLD SUPPLIES BEFORE ANY FURTHER WORK INSPECTIONS. |