Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM04253
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/13/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 04/05/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ NEW 3" FROM EXISTING INTO AND THRU SUBMETERS INTO 7230 - VIP NAILS - 7204 - PERFORMANCE BICYCLES AND 7220 - OFFICE DEPOT OK. INTERMED. YARD WTR FOR ROSS 7250 E. BROADWAY FROM EXISTING MAIN THRU SUBMETER INTO BLD OK. NEED TO SEE CITY APPROVED DRAWING AND TERMINATION OF H2O INTO BIG D - 7140, MICHAELS - 7150, SPORTMART - 7160, HOME GOODS - 7170, OFFICE DEPOT - 7220. | |
| 03/30/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ NEW 3" FROM EXISTING INTO SUBMETER HEADER TO 2" METER FOR OFFICE GOODS (7220) 2½" PVC OVER TO 3' FROM BLD. NEED TO SEE CONNECTIONS INTO ALL BLDS EXPOSE INLET AND OUTLET PIPING FOR 7140, 7150, 7160, 7170, AT SUB METER LOCATION. WILL NEED TO SEE STUB INTO ALL THESE BLDS ALSO. | |
| 03/29/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1" FROM SUB METER FOR 7230 E. BROADWAY (VIP-NAILS) WTR TEST THRU BLDG OK. 1" FROM SUB METER FOR 7204 E. BROADWAY (PERFORMANCE BICYCLES) THRU BLD OK. EXPOSE TIE-INS FROM MAIN TO SUB METERS AND SUB METERS TO 7170, 7160, 7150 AND 7140. | |
| 03/22/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/ 1) CAPS ON DEMO PLUMBING IN SOUTH EAST CORNER FOR OLD SANITARY DRAINAGE OK | |
| 03/08/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* |