Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM04241
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
03/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) RETRO FIT BOLTS REQUIRE SPECIAL INSPECTION EPOXIED RETRO FITS (WILL CHECK AT NEXT INSPECTION) 2) EXTERIOR LATHE OK |
|
02/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | DUE TO OSB BEING EXPOSED EXCESSIVELY TO THE WEATHER, IT APPEARS THAT THE STRUCTURAL INTEGRITY HAS BEEN COMPROMISED; EITHER REPLACE ALL EXTERIOR SHEATHING AND ROOF SHEATHING OR HAVE CERTIFIED ENGINEER VERIFY STRUCTURAL INTEGRITY OF OSB; SUBMIT TO CITY OF TUCSON PLAN CHECK FOR APPROVED; HAVE A COPY ON JOB SITE AND THEN RECALL FOR INSPECTION | |
01/05/2006 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED VERIFICATION OF A35'S AND H2.5'S LEDGER TO STUDS 2) NEED APPROVED TRUSS DRAWINGS 3) REPLACE ALL EXCESSIVELY SPALLED HOLDOWNS WITH APPROVED EPOXIED HOLDOWNS 4) INSTALL DBL CRIPPLE STUD UNDER DBL GIRDER 2ND FLOOR BEARING 5) INSTALL ATTIC VENTS AND VENT BIRD BOARDS 6) NEED LADDER TO INSPECT ROOF 7) STOPPED INSPECTION 8) HOLDOWNS MISSING ALSO |