Permit: T03CM04241

Parcel: 11502479R


Addresses:

417 E LEE ST #01


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM04241

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/29/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
03/02/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) RETRO FIT BOLTS REQUIRE SPECIAL INSPECTION EPOXIED RETRO FITS (WILL CHECK AT NEXT INSPECTION)
2) EXTERIOR LATHE OK
02/02/2007 EXT METAL CLIPS/EXT SHEATHING Denied DUE TO OSB BEING EXPOSED EXCESSIVELY TO THE WEATHER, IT APPEARS THAT THE STRUCTURAL INTEGRITY HAS BEEN COMPROMISED; EITHER REPLACE ALL EXTERIOR SHEATHING AND ROOF SHEATHING OR HAVE CERTIFIED ENGINEER VERIFY STRUCTURAL INTEGRITY OF OSB; SUBMIT TO CITY OF TUCSON PLAN CHECK FOR APPROVED; HAVE A COPY ON JOB SITE AND THEN RECALL FOR INSPECTION
01/05/2006 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED VERIFICATION OF A35'S AND H2.5'S LEDGER TO STUDS
2) NEED APPROVED TRUSS DRAWINGS
3) REPLACE ALL EXCESSIVELY SPALLED HOLDOWNS WITH APPROVED EPOXIED HOLDOWNS
4) INSTALL DBL CRIPPLE STUD UNDER DBL GIRDER 2ND FLOOR BEARING
5) INSTALL ATTIC VENTS AND VENT BIRD BOARDS
6) NEED LADDER TO INSPECT ROOF
7) STOPPED INSPECTION
8) HOLDOWNS MISSING ALSO