Permit: T03CM04232

Parcel: 123020310


Addresses:

2207 N MARGARET AV

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/15/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
12/12/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) SANITARY "T" FITTINGS NOT ALLOWED FOR USE AS HORIZONTAL DRAIN FITTINGS 2) VENT FITTINGS NOT ALLOWED FOR USE BELOW FLOOD RIM OF FIXTURES 3) TUB NOT PROPERLY VENTED 4) DRAIN CANNOT BE INSTALLED PARALLEL UNDER BLDG FOOTING. PROVIDE NAME AND CONTRACT # OF PLUMBER 5) IMPROPER AIR TEST APPLIED FOLLOW UPC OR PROVIDE WATER TEST