Permit: T03CM04230

Parcel: 12212228B

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
04/02/2004 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection 0000*/ OK FOR SHEET ROCK.
03/26/2004 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ YOU MUST HAVE MIN. 1" CLEARANCE AROUND FIREPLACE VENT PIPES. REMOVE SHEETROCK IN UNIT 1 IF NECESSARY TO ACHIEVE 1" CLEARANCE. ALL THREE UNITS FAIL. PAY A RE-INSPECTION FEE PRIOR TO NEXT INSP.
03/22/2004 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) ALL UNITS PROVIDE MINIMUM 1" CLEARANCE FROM WOOD WHERE FIREPLACE VENT PENETRATES THE ROOF 2) RECALL FOR INSPECTION
03/18/2004 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) UNIT 8 AND 10 PROVIDE MINIMUM 1" CLEARANCE FROM WOOD WHERE FIREPLACE FLU PENETRATES THE 2ND FLOOR. ALL UNITS PROVIDE SCREWS WHERE BATHROOM EXHAUST DUCT ATTACHES TO FAN OUTLET. SUPPORT PVC CONDENSATE DRAIN EVERY 4'. INSULATE T WYE ABOVE RESTROOM (ALL UNITS). ALL UNITS PROVIDE BACKING ON SUPPLY BOX IN KITCHEN. RECALL FOR INSPECTION