Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/10/2003 |
FRAMING |
|
Approved |
|
| 10/09/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) TUB SHOW LEAKS 2ND FLOOR, ABOVE FAMILY ROOM 2) BANG PLATE ROMEX REAR WALL 1ST FLOOR ?/PLATE 3) BANG PLATE WATER HEATER, COPPER 4) 2ND FLOOR TUB, BACKING AT TUB SIDES, ALSO GARDEN TUB 5) NEED DWV TEST 6) HOLE IN SERVICE LINE GARAGE WALL PEX 7) PIN HOLE IN WATER SERVICE GATE VALVE JOINT |