10/15/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/13/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) MISSING NAILING FRONT HIP 2) MISSING HANGER SMALL BEAM EAST SIDE 3) BLOCKS NEEDED UNDER NORTH SIDE OF TOWER, AT MAIN HOUSE ROOF FOR B/PLATE 4) PLEASE CUT INSPECTION HOLE REAR COLUMN FOR ANCHORAGE 5) INSTALL LATERAL BRACES